We place our full confidence in the LON network. This is where you will find a complete summary of the LON network products from SCHNEIDER.
| |
 |
BAM-1000 |
| Alarm module SCHNEIDER BAM-1000 alarm modules can be mounted on site wherever required. They are supplied in a surface-mounting housing design (150 x 150 x 50 mm). Along with direct smoke and fire alarms, functions also include the possibility of an integrated flap drive test. Unrestricted configuration of network variables make it possible to assign any number of flap drives to one or more smoke or fire alarms. A fire alarm in an alarm module automatically triggers the monitored closing process of any number of assigned fire protection flaps. This signal is received by the building services management system at the same time and the motor controller releases the appropriate signal to the LON network upon completed closure. The building services management computer initiates the appropriate action and also checks all incoming telegrams for plausibility. This concept guarantees a very high standard of safety for the user. |
| |
 |
BMC-1000 |
| Motor controller The SCHNEIDER BMC-1000 motor controller can operate up to four flap drives (fire protection and/or smoke removal flaps in random array). Switching the motorised flaps on and off is time controlled. The motor current is monitored for permitted levels at the same time. An appropriate fault signal is issued in the bus network if there are any malfunctions. An integrated test function enables easy visual and functional examination of the flap drives in the system. Corresponding LED's signal the status of the respective motor drives. |
| |
 |
CRP300 |
| CRP300 is suitable for self-sufficient regulation of the required positive or negative room pressure. The specification of setpoints is done via the digital inputs, by programming via the service module SVM100 or optionally via the LON network. |
| |
| Quote request text CRP300 - DK-S |
|
|
 |
 |
| Technical datasheet CRP300 |
|
|
|
 |
|
| |
 |
FC500 |
| Control and monitoring of fume hood exhaust air volume
flow or face velocity in relation to the front sash and slide window opening. |
| |
| Operating and installation instructions FC500 |
|
|
|
 |
| Technical datasheet FC500 |
|
|
|
 |
|
| |
 |
FC700 |
| Fume hood controller with integrated web server
Microprocessor based system for control and monitoring of fume hood exhaust air volume flow or face velocity in relation to the front sash and slide window opening. Depending on the configuration different operating modes for fume hood control (e.g. fully variable, face velocity, sash sensor) are possible.
The integrated functional monitoring in accordance with EN 14175 offers maximum safety for laboratory staff. When the exhaust air setpoint that is to be regulated is underrun, an acoustic and optical alarm is activated.
Suitable for all fume hood constructions and extraction
units. Standard model with differential pressure transmitter. |
| |
| Technical datasheet FC700 |
|
|
|
 |
|
| |
 |
GC10 |
| The GC10 room group controller automatically and decentrally balances the setpoints for laboratory room control (room supply and exhaust air). The room air change rate requirements of DIN 1946, Part 7 are taken into account and are freely programmable. Negative room pressure (in laboratories)or positive room pressure (in clean rooms) may be adjusted by a percentage relative to the room exhaust air or with a fixed offset (e.g. 300 m3/h). |
| |
| Technical datasheet GC10 |
|
|
|
 |
|
| |
 |
LCO500 |
| The LCO500 laboratory controller automatically and decentrally balances the setpoints for laboratory room air control room supply air and exhaust air). The room air change rate requirements of DIN 1946, Part 7 are taken into account and are freely programmable. Negative room pressure (in laboratories) or positive room pressure (in clean rooms)may be set by a percentage relative to the room exhaust air or with a fixed offset (e.g. 300 m3/h). |
| |
| Technical datasheet LCO500 |
|
|
|
 |
|
| |
 |
PAD-3000 |
| SCHNEIDER has developed its own software for building management systems to enable optimum connection to the LabSystem product range. The PAD-3000 building services management system guarantees the user the full transparency of an global laboratory system solution. It is used for calling up and regulating relevant laboratory data such as actual exhaust values (laboratory, laboratory extractor, switchable consumers etc.), room temperature, humidity, fault signals and alarms (gas alarm, air too low, fire protection flaps, smoke extractor flaps etc.), remote control in reduced service mode (night-time lowering), front sash closure and parameter assignment to laboratory extractors. |
| |
 |
RMC700 |
| Multi-functional Room Management Controller, digital, LON, Modbus
The multi-functional and user-programmable room management controller takes over the complete operating
mode control and monitoring of a laboratory room.
RMC700 is the HMI (Human Machine Interface) between the laboratory personnel and the building management system
(BMS). The plain text messages with custom graphic symbols (icons) and with multi coloured backlight allowing a
clear and simple priority-driven allocation of the actual operating conditions.
|
| |
| Technical datasheet RMC700 |
|
|
|
 |
|
| |
 |
VAV-L (LON) |
High-speed variable volume flow controller, LON, LON-balancing Available in the following versions: - round, PPs or steel
- rectangle, PPs or steel
Microprocessor controlled, high-speed adaptive control system for variable control of room supply air and room exhaust air volume flows, particularly suitable for clean rooms and laboratories. A high-speed control algorithm compares the setpoint with the actual value measured by a differential pressure transmitter and regulates the flow quickly, precisely and steadily, independent of pressure fluctuations in the duct system. The minimum and maximum volume flow setpoint is freely programmable and is saved mains voltage failure-safe in the EEPROM. |
| |
| Technical datasheet VAV-L |
|
|
|
 |
|
| |
 |
VAV500 |
| Multi-functional high-speed variable air volume controller, analogue, LON, BACnet, Modbus
Available in the following versions: - round, PPs or steel
- rectangle, PPs or steel
Microprocessor controlled, high-speed adaptive control system for variable control of room supply air and room exhaustair volume flows, particularly suitable for clean rooms and laboratories. Advanced requirements need a heating or cooling, and a pressurization of the room. In addition to these features the multi-functional flow Controller VAV500 provide up to 7 analogue inputs 0 (2) ... 10V DC for connecting consumers (e.g. fume hood controller FC500) and calculates the room balance. In network operation (LON,BACnet, Modbus) up to 16 consumers are accounted for.
The retrofit interfaceboards LON, BACnet or Modbus ensure an individual, efficient and cost-effective direct connection to the building management system (BMS). |
| |
| Operating and installation instructions |
|
|
|
 |
| Technical datasheet VAV500 |
|
|
|
 |
|
| |
 |
VCP500 |
| High resolution pressure controller with volume flow limitation
High resolution pressure controller with volume flow limitation and innovative bypass controller for airtight laboratories and clean rooms.
VCP500 is available as a round model and quickly, stably and very precisely regulates up to three programmable constant room pressures.
Particularly suitable for laboratories (S1-S3), clean rooms (classes A-D), animal facilities and air locks.
Optionally VCP500 can be equipped with a LON field bus module (FTT10-A), BACnet (MS/TP) or Modbus (RS485) and thus simplifies connection to the BSM.
|
| |
| Technical datasheet VCP500 |
|
|
|
 |
|
| |
 |
VME300 |
| Volume flow measuring system with analogue output or LON interface
Microprocessor controlled, high-speed volume flow measuring system of room supply air and room exhaust air volume flows in manifolded ducts. Suitable for different measuring tasks, such as fume hoods, safety cabinets and other exhaust air and supply units.
The exhaust air and supply air volume flow is measured very stable and accurate and is as actual analogue value 0 (2) ... 10V DC or in LON-network mode as a standard variable (SNVT) available.
The retrofit interfaceboard LON, BACnet or Modbus ensure an individual, efficient and cost-effective direct connection to the building management system (BMS).
The system data and setpoint values are freely programmable and will be saved voltage fail-safe in the EEPROM. |
| |
| Technical datasheet VME300 |
|
|
|
 |
|
| |